Beta – steps may change The launch hub is a Raspberry Pi 5. A production image on a fresh Pi 5 is still being verified. Power options are the official 27W USB-C plug-in supply, or PoE+ for rack installs. Items marked Coming soon are not live yet.
Safety and use
These sheets are for trained Helix installers. They are not a substitute for local electrical or fire code, or for a licensed electrician or alarm contractor where the job requires one.
- Turn the circuit breaker off and verify the circuit is dead before opening a wall box or touching line-voltage wiring.
- The hub itself is low-voltage (powered by the supplied power supply). Wall tablets on PoE, cameras, and any line-voltage relays, heaters, pumps, or irrigation valves are not.
- Never port-forward ports 8080 or 8090 on the customer’s router. The hub is not meant to sit on the public internet.
- This document contains no passwords, PINs, tokens, camera stream URLs, or device secrets. Use placeholders such as
<HUB-IP>. Get real values only from the Helix credential vault, and enter them only on the customer’s hub. - Do not send garage, lock, heater, or alarm commands on a live house without the homeowner present and a clear go-ahead.
- The alarm features described later in these sheets are built in software but are not released for live monitoring. Do not tell a customer the house is professionally monitored until Helix has said that path is live.
What this sheet covers
How to unbox and power the Helix hub, wire it to the LAN, find it on the network, open Composer and the kiosk, pair the Helix Control app to the relay at relay.helixintegrate.com with the short typed pairing code, activate the device license, check for updates, and complete the one-time legal sign screen.
Programming rooms and devices is Sheet 4. Tablets are Sheets 2 and 3. Installing switches, sensors, cameras, and irrigation is Sheet 5.
1. What the hub is
The Helix Controller Hub is the always-on server for a Helix home. It runs both halves of the system:
| Service | Address | Who uses it |
|---|---|---|
| Kiosk (family dashboard, plus every device driver, scene, and schedule) | http://<HUB-HOSTNAME>.local:8080 or http://<HUB-IP>:8080 |
Wall tablets, iPads, phones |
| Composer (programming tool, PIN-locked) | http://<HUB-HOSTNAME>.local:8090 or http://<HUB-IP>:8090 |
Installer laptop or phone |
The default hostname on a Helix Controller Hub is helix-ch01 Beta – steps may change, so the usual addresses are http://helix-ch01.local:8080 and http://helix-ch01.local:8090.
Beta – confirm with Helix support Some jobs may ship on different approved hardware. These sheets describe the Helix Controller Hub; ask Helix support if your hub is a different model.
Always wire the hub by Ethernet. Wi-Fi is not supported for the hub itself.
2. What’s in the box
Beta – steps may change Typical package (contents may change):
- Helix Controller Hub, with the serial label on the underside.
- Power, as ordered: the official Raspberry Pi 27W USB-C supply (standard plug-in), or a Pi 5-compatible PoE+ HAT or 5 V / 5 A PoE+ USB-C splitter (rack). Use only the power option that shipped with the hub. A phone charger or a weaker supply can cause random restarts.
- Storage with the Helix system image already loaded by Helix.
- Helix setup stick (USB, volume label
HELIX), if this hub is not already installed. - Cat6 Ethernet patch cable.
- Quick-start card with the serial number.
Record the hub serial number and the client name on the job sheet before you start. Do not write passwords on the hub, the stick, or the quick-start card.
Leave about 5 cm (2 in) of clearance around the case. Do not stack the hub directly on other hot gear. See Power options below before you plug anything in.
Power options
The Raspberry Pi 5 needs 5 V at up to 5 A (25.5 W) for full USB peripheral power. Use one of the two options below, not both at the same time.
Standard: USB-C plug-in
Use only the official Raspberry Pi 27W USB-C power supply (5.1 V, 5 A, US plug) that ships with a standard hub. A phone charger, a Raspberry Pi 4 15 W (3 A) supply, or any weaker USB-C supply can cause restarts and limits USB devices to 600 mA.
- Plug the supply into a UPS battery outlet (see Wiring and power).
- Plug the USB-C end into the hub.
- Connect Ethernet for data only, on a normal switch port or any spare port on the PoE switch.
PoE+ for rack installs
Power and network share one Ethernet cable. This needs an IEEE 802.3at PoE+ switch port, which can deliver 25.5 W. A standard 802.3af PoE port (15.4 W) is not enough.
Use one of these, both 5 V / 5 A and 802.3at:
- A Pi 5-compatible PoE+ HAT (for example Waveshare PoE HAT (H), isolated). The official Raspberry Pi PoE+ HAT made for Pi 4 and 3B+ does not fit the Pi 5 (the PoE header moved) and only supplies 5 V / 4 A. Do not use it.
- Or a PoE+ USB-C splitter, 5 V / 5 A, 802.3at, with gigabit Ethernet. This keeps the official USB-C power jack and stays low enough for a tight 1U tray. Do not use a 5 V / 2 A or 5 V / 3 A splitter.
- Confirm the switch port is PoE+ (802.3at, 25.5 W), not af-only and not a data-only port.
- Put the PoE+ switch on the UPS battery outlets. The hub then rides on the switch; do not rely on a wall wart for the hub.
- HAT: connect the hub Ethernet port to that PoE+ port. Splitter: connect the PoE input to that port, the splitter’s USB-C output to the hub, and the splitter’s LAN output to the hub Ethernet port.
- Do not also plug in the 27W USB-C supply.
The official Raspberry Pi 5 case fits the Waveshare PoE HAT (G), (H) and (J). A 19-inch 1U Pi tray can be tight: some taller HATs have shorted against the equipment above. If the HAT does not clear the tray, use the USB-C splitter instead. Confirm fit on the actual tray before leaving the shop.
Beta – steps may change If USB devices other than a low-power radio dongle need the full 1.6 A budget, the hub may need a firmware USB current override when power does not come from the official 27W PD supply. Ask Helix support before changing that setting.
3. Wiring and power (including battery backup)
The wall tablet that shows the kiosk (and, later, the alarm panel) is usually powered by a PoE switch. If the power goes out and that switch is not on a UPS, the tablet goes dark. Every job should put a battery backup (UPS) on the PoE switch that powers the kiosk tablet, and on the hub, the router, and the Wi-Fi access points that sensors and tablets use.
3.1 Rack wiring
- Plug the UPS into a grounded wall outlet. Use a line-interactive or online UPS. Prefer a pure sine wave unit.
- Plug these into the UPS battery outlets, not into a surge-only strip: the router or firewall, the PoE switch, the Wi-Fi access points (or their injectors), and — for a standard plug-in hub — the official 27W supply. For a PoE+ hub, the switch carries the hub; the switch must be on the UPS. See Power options.
- Standard plug-in: connect the hub Ethernet port to a normal (data) switch port. PoE+ rack: connect the hub or the USB-C splitter to an 802.3at PoE+ port (25.5 W), as described in Power options.
- Connect wall tablets and PoE cameras to PoE ports on the same LAN (or to a VLAN that can still reach the hub — see section 4).
- In the router, create a DHCP reservation for the hub so its address never changes. Tablets are bookmarked to that address.
3.2 Recommended UPS runtime chart (estimates only)
Runtimes below are estimates, not measurements. They use:
Estimated hours = (battery watt-hours × 0.85) ÷ load watts
The 0.85 factor is a simple allowance for inverter and battery losses. Actual time varies with UPS efficiency, battery age, temperature, and the real watt draw of your gear. Always check the UPS and device nameplates, then do a short pull-the-plug test before you leave the job.
Estimated typical loads (use nameplate or a Kill-A-Watt when you can):
| Package | What is on the UPS | Estimated load |
|---|---|---|
| A. Tablet path | PoE switch + 1 wall tablet | 25 W |
| B. Network core | A + router/firewall + 1 Wi-Fi AP | 52 W |
| C. Hub + core | B + Helix hub | 64 W |
| D. Small camera set | C + 4 PoE cameras | 88 W |
| E. Typical house | C + 8 PoE cameras + 2 extra tablets + 1 extra AP | 144 W |
Estimated runtime
| Battery size | Usable Wh (× 0.85) | A · 25 W | B · 52 W | C · 64 W | D · 88 W | E · 144 W |
|---|---|---|---|---|---|---|
| 150 Wh | 128 | 5.1 h | 2.5 h | 2.0 h | 1.5 h | 0.9 h |
| 300 Wh | 255 | 10.2 h | 4.9 h | 4.0 h | 2.9 h | 1.8 h |
| 500 Wh | 425 | 17.0 h | 8.2 h | 6.6 h | 4.8 h | 3.0 h |
| 800 Wh | 680 | 27.2 h | 13.1 h | 10.6 h | 7.7 h | 4.7 h |
| 1,000 Wh | 850 | 34.0 h | 16.3 h | 13.3 h | 9.7 h | 5.9 h |
| 1,500 Wh | 1,275 | 51.0 h | 24.5 h | 19.9 h | 14.5 h | 8.9 h |
Size the battery in watt-hours (Wh), not just VA. Many small 450–650 VA desktop UPS units hold far less energy than their VA number suggests (often in the 150–300 Wh range).
Practical target: keep the hub, router, PoE switch, access points, and every kiosk tablet up for a typical outage. 30 minutes is the minimum. 2–4 hours is a better target when the tablet will be used as the alarm keypad, or when Wi-Fi sensors need the router and AP to stay up. Zigbee sensors can keep talking to a hub that has its own USB radio and is still on the UPS, even if Wi-Fi is down. Beta – confirm with Helix support Whether your hub includes a Zigbee radio depends on how it was ordered; ask Helix support.
After install, pull the UPS input for two minutes and confirm: the hub still answers on :8080 and :8090, the wall tablet stays on, and the router and AP stay up.
4. Prepare the network first
Most “device offline” calls come from an IP that changed or from Wi-Fi isolation.
- Give the hub a DHCP reservation (or a static IP). Write
<HUB-IP>on the job sheet. - Keep a 2.4 GHz SSID (or 2.4 GHz enabled on a mixed SSID). Tuya, Shelly, and most IR blasters are 2.4 GHz only.
- Do not port-forward 8080, 8090, or SSH on the router.
- If you use an IoT VLAN, allow the hub to reach those devices, and allow tablets to reach the hub on port 8080. Shelly discovery uses mDNS, so either keep Shelly devices on the same segment as the hub or enter their IPs by hand.
- Also reserve addresses for cameras, the HDMI matrix (if any), and WiiM / Sonos players.
- Place access points so each wall tablet has a strong signal (better than about −65 dBm).
5. If the hub is already imaged
Many units ship with the system already installed. If the status light is already a slow heartbeat, skip to section 7.
- Connect Ethernet first, then the supplied power supply.
- Wait for the status light to show a slow heartbeat (a double blink, repeated). That means the kiosk and Composer services are running.
- Do not unplug while the light is a solid or irregular flicker (startup or update).
6. If you must write the image and run first boot
Beta – steps may change This install path is still being verified on production hardware. Steps may change. Most hubs ship already imaged (section 5).
Skip this section when the storage is already loaded.
6.1 System image
Coming soon. Helix loads the system image onto the hub before it ships. Installer instructions for re-imaging the current hub are being finalized. If a hub has no image, contact Helix support; do not try to flash it yourself.
6.2 Prepare the Helix setup stick
- Format a USB stick (8 GB or larger) as FAT32 or exFAT with the volume label
HELIX(capitals, exactly). - Unzip
Helix-hub-USB.zipto the root of the stick. - Open
helix.confand check at least:
| Setting | Default | Meaning |
|---|---|---|
HUB_HOSTNAME |
helix-ch01 |
Announced as <name>.local |
KIOSK_PORT / COMPOSER_PORT |
8080 / 8090 |
Dashboard and Composer |
MOCK_MODE |
0 |
1 is demo mode (no real device commands). Keep 0 at a client’s house. |
AUTO_INSTALL |
yes |
A HELIX stick plugged in later runs install or update automatically |
TIMEZONE |
America/Chicago |
Schedules and sunrise/sunset |
FIREWALL |
yes |
Only the home LAN and the remote-access path can reach the hub |
INSTALL_TAILSCALE |
no |
Leave at no. The phone path is the Helix relay (section 9). Beta – confirm with Helix support Ask Helix support before turning on any other remote path. |
- The stick holds no passwords, PINs, keys, or camera links. Optional: copy a client project backup (
*.helix.json) intoprojects/so it imports on install.
6.3 First boot and automatic install
- Connect Ethernet. Insert the HELIX stick in a USB port.
- Connect power. The hub starts up (the status light, if fitted, flickers).
- If the first-boot hook is present, the installer starts by itself. Otherwise sign in over SSH (
ssh <ADMIN-USER>@helix-ch01.local) and run:
sudo mount -L HELIX /mnt && sudo bash /mnt/install.sh
- Wait 5–10 minutes. The installer needs internet for the software runtime. Do not unplug.
- At the end it prints a new kiosk/Composer PIN. Write that PIN on the job sheet only. It is also stored on the hub at
/etc/helix/initial-pin. Change it later in Kiosk Settings, and give the new PIN to the homeowner only at handoff. - When the status light shows a slow heartbeat, the hub is ready. Remove the stick.
The installer is safe to run again. It does not overwrite a PIN, secrets file, layout, or project already on the hub. If MOCK_MODE was left at 1, device cards will say “demo” and nothing will switch; set it to 0 and run the installer again.
7. Finding the hub
- From a laptop or phone on the same network, open
http://helix-ch01.local:8090. - Log in to Composer with the kiosk PIN (the one from first boot, or the one already on this hub).
- If
.localnames do not resolve (common on some Android devices and some guest VLANs), look up the hub in the router’s DHCP client list (namehelix-ch01) and openhttp://<HUB-IP>:8090. - Confirm the kiosk the same way:
http://helix-ch01.local:8080orhttp://<HUB-IP>:8080.
If several hubs share one network, each must have its own HUB_HOSTNAME.
Status light
Beta – steps may change The current hub may not have a status light. If there is none, treat http://<HUB-IP>:8080 loading as the check. The table below may change.
| Light | Meaning |
|---|---|
| Slow heartbeat (double blink) | Healthy: kiosk and Composer are running |
| Fast blink | A service or health check failed. Run helix-verify over SSH. |
| Solid or irregular flicker | Starting, installing, or updating. Do not unplug. |
| Off | No power, or the hub has halted. Check the supply and the UPS. |
8. Opening Composer and the kiosk
- Composer (
:8090) is PIN-locked. Enter the kiosk PIN on the keypad. If no PIN exists yet, Composer stays locked. - Changes in Composer save automatically (the header shows “Saved” with the time). Tablets see nothing until you Send to tablets (Sheet 4).
- The kiosk (
:8080) is the family dashboard. On a laptop it is a preview; the customer will use wall tablets and phones (Sheets 2 and 3). - Deep links, once a project exists: Composer
http://<HUB-IP>:8090/#<projectId>/<section>and kioskhttp://<HUB-IP>:8080/?room=<roomId>.
9. Pairing to the relay (phone access away from home)
Beta – steps may change Coming soon Signing in to the app away from home is being fixed and is not reliable yet. Steps may change.
Remote access for the Helix Control app (also called Helix Home in some screens) goes through Helix’s relay at relay.helixintegrate.com. The hub is not exposed to the public internet. Composer itself is never reachable through the relay. Garage doors, locks, and heat used remotely still require a Face ID confirm on the phone.
Beta – confirm with Helix support The app is called Helix Control in most places and Helix Home on some screens. How customers install it (TestFlight or the App Store) is still being finalized. Ask Helix support for the current install link.
9.1 Turn remote access on
- In Composer, open Remote access (System / the Remote access control).
- Turn on Allow the Helix Home app to reach this hub away from home.
- Confirm the panel shows the relay host and that the agent is installed. If it says the remote agent is not installed, stop and get a Helix staff image or agent install — do not invent a workaround on the customer’s router.
- Wait until the status is connected, or stay on the panel while you pair (the codes appear once the hub is registered and not yet owned).
9.2 Pair the phone with the short typed code
The hub issues two codes that represent one pairing, and they expire together (default 15 minutes):
- A QR / claim code, for scanning in the app.
- A typed short code: 6 characters from
ABCDEFGHJKMNPQRSTUVWXYZ23456789(no0,O,1,I, orL), shown asABC-123.
Either code works once. Using one cancels the other. Five wrong guesses delete the pairing. Never photograph a live code for a group chat or a ticket, and never print a real code in a manual. The example ABC-123 is the format only.
- On the phone, install Helix Control / Helix Home and sign in to the installer’s or homeowner’s Helix account.
- Start pairing and either scan the QR code, or tap Enter code instead and type the short code (spaces and dashes are fine:
ABC-123,abc123, orABC 123). - Give the hub a plain name such as
Home. The phone should show that the hub is paired. - Confirm in Composer’s Remote access panel that the hub is owned / paired.
- From an off-home connection (phone cellular, Wi-Fi off), open the app and confirm the kiosk loads. Then confirm that Composer is still only available on the LAN (or over an approved support path), not in the app’s remote session.
If the code expires, turn Remote access off and on, or reopen the panel, and pair again with a fresh code.
10. License and device activation
Beta – steps may change
Each hub has a device fingerprint. A signed Helix license file must match that fingerprint.
- On the kiosk, look at the top of the screen after a reload. A licensed hub shows no license banner.
- If you see Helix license: grace period — N days remaining, the hub is still fully usable, but the license is missing, mismatched, expired, or not yet verified. You have 30 days from the first unlicensed check. Contact Helix Integration and get a license issued for this hub. Do not copy a license file from another hub — that produces a mismatch.
- If you see Helix unlicensed, the grace period has ended. Non-safety features show the banner; alarm, locks, and safety controls stay available. Contact Helix Integration.
- Helix staff match a signed
license.jsonto the hub’s fingerprint (/api/license/deviceon the hub). Installers should not edit fingerprint or license files by hand.
Beta – confirm with Helix support The license request and activation process is still being finalized. Contact Helix support; do not edit license files by hand.
11. Check for updates
Beta – steps may change Coming soon The update channel is being refreshed. Do not install an update unless Helix support has told you to.
- In Composer go to Installer → Settings → Check for updates (or the Check for updates control).
- Tap Check for updates. The card reports one of: - Up to date — this hub already runs the newest published release. - Update available — a newer release is published. The card shows the new version and what this hub is running. - Can’t check / an error — the hub could not reach the release list. Check the hub’s internet path and try again.
- Opening the panel only checks. It does not install anything by itself.
- If an update is available and the customer has approved it, use the install button on that same panel. The hub takes a backup first, installs the new release, and runs a health check. If the health check fails, the hub rolls itself back automatically.
- Do not install an update in the middle of a live demo. After an update, refresh each tablet.
A USB stick update is also supported on hub: copy the release archive into updates/ on a stick labelled HELIX and plug it in (AUTO_INSTALL=yes), or run the stick’s update.sh. Client data (PIN, secrets, layout, projects) is not overwritten by an update or a rollback.
12. The accept-once legal sign screen
Beta – steps may change
The first time someone uses a hub that has a published disclosure, Helix shows a full-screen sign screen.
- Open the kiosk or the Helix Control app on a phone that can reach the hub.
- Tap Read the full document and scroll to the end. The agreement boxes stay disabled until the document has been opened.
- Tick every required box (the current document uses 14 boxes). Type the signer’s full legal name and the account PIN.
- Tap I Agree. The button stays disabled until the document has been read, every required box is ticked, and the name and PIN are filled.
- After a successful accept, this screen should not appear again on that hub for the same document version. A major new version can show a “what changed” notice and lock doors, heaters, and vehicle start until it is signed again. Status reads and emergency-off stay available.
- Until the disclosure is signed, the hub refuses protected actions (doors, heaters, vehicle control) with an error (
428). Signing is required before you demonstrate those features to the customer. - Small risk banners on doors, heaters, and vehicles can be dismissed with ×. Dismissal is remembered for the current disclosure version only.
Beta – confirm with Helix support The wording on the sign screen is not final legal language yet. Ask Helix support before presenting it to a customer.
13. Quick checks before you leave the rack
http://<HUB-IP>:8080andhttp://<HUB-IP>:8090both load.- The status light is a slow heartbeat.
- The hub has a DHCP reservation.
- The UPS holds the hub, router, PoE switch, and APs. A two-minute pull-the-plug test passed.
- Remote pairing is done, or you have a plan to pair the homeowner’s phone at handoff.
- There is no license mismatch banner, or a license request is already in with Helix.
- Updates have been checked.
- The legal disclosure is signed, or you will have the homeowner sign it on their phone at handoff (their PIN is required).
MOCK_MODEis0on a live house.
14. Troubleshooting
| Symptom | What to do |
|---|---|
helix-ch01.local is not found |
Use <HUB-IP> from the router DHCP list. Confirm the hub is wired and on the same VLAN. mDNS is often blocked between VLANs. |
| Status light fast blink | Over SSH, run helix-verify. Services restart on their own within a few seconds. |
| Install stopped | Usually no internet. Fix the path and run install.sh again (safe). |
| HELIX stick ignored | Volume label must be exactly HELIX. AUTO_INSTALL must be yes. |
| Random restarts | Use only the power supply supplied with the hub. Check the UPS. |
| Forgot the PIN | The initial PIN is on the hub at /etc/helix/initial-pin. Do not write it in a ticket or a group chat. |
| Cards say “demo” / devices do nothing | MOCK_MODE is on. Set it to 0 and re-run the installer. |
| License mismatch | Do not copy another hub’s license file. Ask Helix to issue one for this fingerprint. |
| Pairing code rejected | It expired (15 minutes), was already used, or had five wrong guesses. Request a new code. |
| Phone works at the house but not away | Remote access is off, the agent is not connected, or the phone is not paired. Composer will not open through the relay — that is expected. |
Next: set up wall tablets (Sheet 2, Android, or Sheet 3, iPad), then program the house in Composer (Sheet 4).